Re: [cisco-ttl] Re: Frame Relay Hatası

From: erdem aslan <erdem.aslan_at_....>
Date: Tue, 5 Aug 2008 06:47:32 -0700 (PDT)

Merhaba,
 
"PVC STATUS = DELETED"  buradaki "deleted"  Türk Telekom Frame Relay switchi ile sizin lokasyonunuz arasındaki pvc'nin down olduğunu gösterir. Sorun, Türk Telekom'un layer 2 tanımlarındadır, ilk etapta DLCI numarasının 101 olup olmadığını Türk Telekom ile teyit edin.  
PVC Status'un tüm state'leri ve açıklamaları aşağıdaki gibidir. Kolay gelsin...
 
The router updates its map table with one of three possible LMI connection states:  
Active:The connection is active, and the routers can exchange data through the PVC.  
Inactive:The local connection to the Frame Relay switch is working, but the remote end of the PVC is not communicating to the Frame Relay switch.  
Deleted:No LMI keepalive information from the switch to the router is being received for this PVC. This could be because no LMI is actually being exchanged or because the DLCI is not configured on the ingress switch. (Either the Local Management Interface (LMI) is not exchanged between the router and the local switch, or the switch does not have the DLCI configured on the local frame relay switch.) OR The PVC is not configured on the local router.  
STATIC: no keepalive configured on the frame-relay interface of the router.  
 
--- On Mon, 8/4/08, yozbilgin <yusuf_at_gunesbilgisayar.com.tr> wrote:

From: yozbilgin <yusuf_at_gunesbilgisayar.com.tr> Subject: [cisco-ttl] Re: Frame Relay Hatası To: cisco-ttl_at_yahoogroups.com
Date: Monday, August 4, 2008, 5:44 PM

Mrb Devrim,

İstediğin çıktılar aşağıda.

İlgin için teşekkürler.

Yusuf

router#sh int ser 0
Serial0 is up, line protocol is down
  Hardware is PowerQUICC Serial
  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,

     reliability 252/255, txload 1/255, rxload 1/255   Encapsulation FRAME-RELAY, loopback not set   Keepalive set (10 sec)
  LMI enq sent 16487, LMI stat recvd 0, LMI upd recvd 0, DTE LMI down   LMI enq recvd 0, LMI stat sent 0, LMI upd sent 0   LMI DLCI 0 LMI type is ANSI Annex D frame relay DTE   Broadcast queue 0/64, broadcasts sent/dropped 5/1, interface broadcasts 3
  Last input never, output 00:00:07, output hang never   Last clearing of "show interface" counters 1d21h   Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: weighted fair
  Output queue: 0/1000/64/0 (size/max total/threshold/drops)

     Conversations  0/1/256 (active/max active/max total)
     Reserved Conversations 0/0 (allocated/max allocated)
  5 minute input rate 0 bits/sec, 0 packets/sec   5 minute output rate 0 bits/sec, 0 packets/sec
     1 packets input, 28 bytes, 0 no buffer
     Received 0 broadcasts, 10914 runts, 0 giants, 0 throttles
     259524 input errors, 244531 CRC, 11058 frame, 0 overrun, 0 
ignored, 3935 
ab                                                                    
          ort
     16560 packets output, 237491 bytes, 0 underruns
     0 output errors, 0 collisions, 5498 interface resets
     0 output buffer failures, 0 output buffers swapped out
     2 carrier transitions
     DCD=up  DSR=up  DTR=up  RTS=up  CTS=up


router#sh frame pvc 101

PVC Statistics for interface Serial0 (Frame Relay DTE)

DLCI = 101, DLCI USAGE = LOCAL, PVC STATUS = DELETED, INTERFACE = Serial0.1

  input pkts 0             output pkts 73           in bytes 0
  out bytes 6673           dropped pkts 0           in FECN pkts 0
  in BECN pkts 0           out FECN pkts 0          out BECN pkts 0
  in DE pkts 0             out DE pkts 0
  out bcast pkts 5          out bcast bytes 2397
  pvc create time 1d21h, last time pvc status changed 1d19h

debug frame-relay lmi Çıktısı

00:25:23: Serial0(out): StEnq, myseq 23, yourseen 0, DTE down
00:25:23: datagramstart = 0x2571C94, datagramsize = 14
00:25:23: FR encap = 0x00010308
00:25:23: 00 75 95 01 01 00 03 02 17 00
00:25:23:
00:25:33: Serial0(out): StEnq, myseq 24, yourseen 0, DTE down
00:25:33: datagramstart = 0x2571C94, datagramsize = 14
00:25:33: FR encap = 0x00010308
00:25:33: 00 75 95 01 01 00 03 02 18 00
00:25:33:
00:25:43: Serial0(out): StEnq, myseq 25, yourseen 0, DTE down
00:25:43: datagramstart = 0x2571F14, datagramsize = 14
00:25:43: FR encap = 0x00010308
00:25:43: 00 75 95 01 01 00 03 02 19 00
00:25:43:

0:25:53: Serial0(out): StEnq, myseq 26, yourseen 0, DTE down
00:25:53: datagramstart = 0x2571F14, datagramsize = 14
00:25:53: FR encap = 0x00010308
00:25:53: 00 75 95 01 01 00 03 02 1A 00
00:25:53:
00:26:03: Serial0(out): StEnq, myseq 27, yourseen 0, DTE down
00:26:03: datagramstart = 0x2571F14, datagramsize = 14
00:26:03: FR encap = 0x00010308
00:26:03: 00 75 95 01 01 00 03 02 1B 00
00:26:03:
00:26:13: Serial0(out): StEnq, myseq 28, yourseen 0, DTE down
00:26:13: datagramstart = 0x2571F14, datagramsize = 14
00:26:13: FR encap = 0x00010308
00:26:13: 00 75 95 01 01 00 03 02 1C 00
00:26:13:
00:26:23: Serial0(out): StEnq, myseq 29, yourseen 0, DTE down
00:26:23: datagramstart = 0x2571F14, datagramsize = 14
00:26:23: FR encap = 0x00010308
00:26:23: 00 75 95 01 01 00 03 02 1D 00
00:26:23:

0:26:33: Serial0(out): StEnq, myseq 30, yourseen 0, DTE down
00:26:33: datagramstart = 0x2571F14, datagramsize = 14
00:26:33: FR encap = 0x00010308
00:26:33: 00 75 95 01 01 00 03 02 1E 00
00:26:33:


router#sh ver
Cisco Internetwork Operating System Software IOS (tm) C1700 Software (C1700-Y-M), Version 12.1(3), RELEASE SOFTWARE (fc1) Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Wed 05-Jul-00 17:07 by cmong
Image text-base: 0x80008088, data-base: 0x805CDB90

ROM: System Bootstrap, Version 12.0(3)T, RELEASE SOFTWARE (fc1)

router uptime is 4 minutes
System returned to ROM by reload
System image file is "flash:c1700-y-mz.121-3"

cisco 1720 (MPC860) processor (revision 0x501) with 36864K/12288K bytes of memory.
Processor board ID JAD04370I9U (1197538721), with hardware revision 0000 M860 processor: part number 0, mask 32 Bridging software. X.25 software, Version 3.0.0.
1 FastEthernet/IEEE 802.3 interface(s)
1 Serial(sync/async) network interface(s) 32K bytes of non-volatile configuration memory.
4096K bytes of processor board System flash (Read/Write)

Configuration register is 0x2102

router#sh diag
Slot 0:

        C1720 1FE Mainboard Port adapter, 2 ports
        Port adapter is analyzed
        Port adapter insertion time unknown
        EEPROM contents at hardware discovery:
        Hardware Revision        : 5.1
        PCB Serial Number        : JAD04370I9U
        Part Number              : 73-3201-05
        Board Revision           : E0
        Fab Version              : 04
        EEPROM format version 4
        EEPROM contents (hex):
          0x00: 04 FF 40 00 B2 41 05 01 C1 8B 4A 41 44 30 34 33
          0x10: 37 30 49 39 55 82 49 0C 81 05 42 45 30 02 04 FF
          0x20: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
          0x30: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
          0x40: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
          0x50: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
          0x60: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
          0x70: FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF

        WIC Slot 0:
        Serial 1T WAN daughter card
        Hardware revision 1.0   Board revision B0
        Serial number     0033400235    Part number    800-01514-02
        Test history      0x00          RMA number     00-00-00
        Connector type    WAN Module
        EEPROM format version 1
        EEPROM contents (hex):
        0x20:   01 02 01 00 01 FD A5 AB 50 05 EA 02 00 00 00 00
        0x30:   58 00 00 00 05 04 10 01 FF FF FF FF FF FF FF FF

--
Cisco Teknik Tartisma Listesi (Cisco-ttl)

Bu listede onerilen degisikliklerin uygulanmasindaki tum sorumluluk 
kullaniciya aittir. Liste yoneticileri, oneride bulunan liste uyeleri ya da 
bu uyelerin calistigi kuruluslar herhangi bir sekilde sorumlu
tutulamazlar.Yahoo! Groups Links






      

[Non-text portions of this message have been removed]
Received on Fri Aug 08 2008 - 21:57:32 CEST

This archive was generated by hypermail 2.2.0 : Fri Aug 08 2008 - 21:57:33 CEST