[cisco-ttl] Content CMS Kart Arızası

From: ersan tombalak <tombalak80_at_....>
Date: Tue May 30 2006 - 08:39:39 EEST


Merhaba 6509 üzerinde slot 5 üzerinde bulunan CMS kartımız birdenbire arızaya düŸtü. Yedek Ÿase ve supla denememize raŸmen açılmıyor.    

  CMS hakkında bilgili olan arkadaŸların yardımını bekliyorum.    

  Contentle ile ilgili bilgiler    

  Contentle ilgili bilgiler.....(Kırmızı satırlarda Slot 5 teki csm ile ilgili hatalar görülmektedir...)        

  00:00:42: RP: Currently running ROMMON from S (Gold) region 00:00:51: %SYS-5-CONFIG_I: Configured from memory by console 00:00:53: %SYS-5-RESTART: System restarted -- Cisco Internetwork Operating System Software IOS (tm) c6sup2_rp Software (c6sup2_rp-JS-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 06:25 by hqluong
00:00:04: %OIR-SP-6-CONSOLE: Changing console ownership to route processor            

  00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start

00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload =   91 seconds
00:00:46: SP: SP: Currently running ROMMON from S (Gold) region
00:00:52: %SYS-SP-5-RESTART: System restarted --
Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong
00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray
00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2
00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on.
00:00:58: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed.  Attempting to diagnose the source of the problem and recover if possible.
00:00:58: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel.  It has been disabled. Replace the line card.
00:00:58: %SM-SP-4-BADEVENT: Event 'powered_off' is invalid for the current state 'check_power_on': cygnus_oir_bay slot5

-Traceback= 4024CEFC 4023E1BC 403FFC24 406D0718 400FCD64 400FCD50
00:00:58: SP: Last transition recorded: (insert)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (yes_power)-> check_power_on 
00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset)
00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online
00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset)
00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online
00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset)
00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online
00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset)
00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online
00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset)
00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online
00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset)
00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online
00:00:59: %OIR-SP-6-PWRFAILURE: Module 5 is being disabled due to power convertor failure
00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online
00:00:59: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request)
00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online
00:01:08: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics...
00:01:13: %SNMP-5-MODULETRAP: Module 1 [Up] Trap
00:01:13: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics
00:01:13: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
00:01:29: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimum Online Diagnostics...
00:01:38: %SNMP-5-MODULETRAP: Module 9 [Up] Trap
00:01:38: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
00:01:38: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
CY-SB-6509>en
Password:       
00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start
00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 3343 seconds
00:00:46: SP: SP: Currently running ROMMON from S (Gold) region
00:00:52: %SYS-SP-5-RESTART: System restarted --
Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong
00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray
00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2
00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on.
00:01:05: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed.  Attempting to diagnose the source of the problem and recover if possible.
00:01:06: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel.  It has been disabled. Replace the line card.
00:01:06: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request)
00:01:06: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset)
00:01:06: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset)
00:01:06: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset)
00:01:06: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset)
00:01:07: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset)
00:01:07: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset)
00:01:07: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset)
00:01:07: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset)
00:01:08: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics...
00:01:15: %SNMP-5-MODULETRAP: Module 1 [Up] Trap
00:01:15: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics
00:01:15: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
00:01:39: %DIAG-SP-6-RUN_MINIMUM: Module 2: Running Minimum Online Diagnostics...
00:01:40: %DIAG-SP-6-RUN_MINIMUM: Module 4: Running Minimum Online Diagnostics...
00:01:40: %DIAG-SP-6-RUN_MINIMUM: Module 3: Running Minimum Online Diagnostics...
00:01:44: %SNMP-5-MODULETRAP: Module 2 [Up] Trap
00:01:44: %DIAG-SP-6-DIAG_OK: Module 2: Passed Online Diagnostics
00:01:44: %OIR-SP-6-INSCARD: Card inserted in slot 2, interfaces are now online
00:01:49: %SNMP-5-MODULETRAP: Module 4 [Up] Trap
00:01:49: %DIAG-SP-6-DIAG_OK: Module 4: Passed Online Diagnostics
00:01:49: %OIR-SP-6-INSCARD: Card inserted in slot 4, interfaces are now online
00:01:50: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimum Online Diagnostics...
00:01:53: %SNMP-5-MODULETRAP: Module 3 [Up] Trap
00:01:53: %DIAG-SP-6-DIAG_OK: Module 3: Passed Online Diagnostics
00:01:53: %OIR-SP-6-INSCARD: Card inserted in slot 3, interfaces are now online
00:02:02: %SNMP-5-MODULETRAP: Module 9 [Up] Trap
00:02:02: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
00:02:02: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
CY-SB-6509>    

  CY-SB-6509#

00:15:06: %OIR-SP-6-REMCARD: Card removed from slot 5, interfaces disabled
00:15:19: %SNMP-5-MODULETRAP: Module 2 [Down] Trap
00:15:19: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed.  Attempting to diagnose the source of the problem and recover if possible.
00:15:19: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel.  It has been disabled. Replace the line card.
00:15:19: %SM-SP-4-BADEVENT: Event 'powered_off' is invalid for the current state 'check_power_on': cygnus_oir_bay slot5

-Traceback= 4024CEFC 4023E1BC 403FFC24 406D0718 400FCD64 400FCD50
00:15:19: SP: Last transition recorded: (remove)-> empty (remove)-> empty_clr_persist (remove)-> empty (insert)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (yes_power)-> check_power_on (timer)-> check_power_on (timer)-> check_power_on 
00:15:19: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset)
00:15:19: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset)
00:15:19: %OIR-SP-6-PWRFAILURE: Module 5 is being disabled due to power convertor failure
00:15:19: SP: oir_disable_notice: slot5: lcp failed to go online
00:15:19: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request)
00:15:19: %SNMP-5-MODULETRAP: Module 3 [Down] Trap
00:15:19: SP: oir_disable_notice: slot5: lcp failed to go online
00:15:20: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset)
00:15:20: %SNMP-5-MODULETRAP: Module 4 [Down] Trap
00:15:20: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset)
00:15:21: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset)
00:15:21: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset)
00:15:21: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset)
00:15:21: %SNMP-5-MODULETRAP: Module 9 [Down] Trap
00:15:21: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset)
CY-SB-6509#
CY-SB-6509#

CY-SB-6509#
CY-SB-6509#sh module ContentSwitchingModule 5 reals    
  real                  server farm      weight  state          conns/hits

-------------------------------------------------------------------------
 CSM module is offline.    

  CY-SB-6509#sh module ContentSwitchingModule 5 reals    

  00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start

00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 4434 seconds
00:00:46: SP: SP: Currently running ROMMON from S (Gold) region
00:00:52: %SYS-SP-5-RESTART: System restarted --
Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong
00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray
00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2
00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on.
00:00:58: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed.  Attempting to diagnose the source of the problem and recover if possible.
00:00:58: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel.  It has been disabled. Replace the line card.
00:00:58: %SM-SP-4-BADEVENT: Event 'powered_off' is invalid for the current state 'check_power_on': cygnus_oir_bay slot5

-Traceback= 4024CEFC 4023E1BC 403FFC24 406D0718 400FCD64 400FCD50
00:00:58: SP: Last transition recorded: (insert)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (yes_power)-> check_power_on 
00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset)
00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online
00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset)
00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online
00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset)
00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online
00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset)
00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online
00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset)
00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online
00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset)
00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online
00:00:59: %OIR-SP-6-PWRFAILURE: Module 5 is being disabled due to power convertor failure
00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online
00:00:59: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request)
00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online
00:01:08: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics...
00:01:14: %SNMP-5-MODULETRAP: Module 1 [Up] Trap
00:01:14: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics
00:01:14: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
   

  00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start

00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 4617 seconds
00:00:46: SP: SP: Currently running ROMMON from S (Gold) region
00:00:52: %SYS-SP-5-RESTART: System restarted --
Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong
00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray
00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2
00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on.
00:01:00: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (Reset)
00:01:07: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics...
00:01:13: %SNMP-5-MODULETRAP: Module 1 [Up] Trap
00:01:13: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics
00:01:13: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online
00:01:15: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed.  Attempting to diagnose the source of the problem and recover if possible.
00:01:15: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel.  It has been disabled. Replace the line card.
00:01:15: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request)
00:01:15: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset)
00:01:15: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset)
00:01:16: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset)
00:01:16: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset)
00:01:16: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset)
00:01:16: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset)
00:01:17: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset)
00:01:17: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset)
   
  CY-SB-6509#sh module 
Mod Ports Card Type                              Model              Serial No.

--- ----- -------------------------------------- ------------------ -----------
1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-SUP2-2GE SAL09497B9D 2 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06200P5A 3 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06200P3V 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAD043601HW 5 0 SLB Application Processor Complex WS-X6066-SLB-APC SAD07130007 9 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 SAD043302DA Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
1 0015.c6b3.aa24 to 0015.c6b3.aa25 5.3 7.1(1) 12.1(26)E5 Ok 2 0009.1266.1f98 to 0009.1266.1f9f 2.1 5.4(2) 8.5(0.9)TFW3 Ok 3 0009.1266.1e50 to 0009.1266.1e57 2.1 5.4(2) 8.5(0.9)TFW3 Ok 4 00d0.c0d2.dff4 to 00d0.c0d2.dffb 1.3 5.4(2) 8.5(0.9)TFW3 Ok 5 0002.7ee5.0d64 to 0002.7ee5.0d6b 1.6 Unknown Unknown PwrDown 9 0030.19de.4dc4 to 0030.19de.4df3 1.1 5.4(2) 8.5(0.9)TFW3 Ok Mod Sub-Module Model Serial Hw Status
--- --------------------------- --------------- --------------- ------- -------
1 Policy Feature Card 2 WS-F6K-PFC2 SAL09507N7J 3.5 Ok 1 Cat6k MSFC 2 daughterboard WS-F6K-MSFC2 SAL1004BCT6 2.9 Ok

  Mod Online Diag Status
--- -------------------

  1 Pass
  2 Pass
  3 Pass
  4 Pass
  5 Unknown
  9 Pass

CY-SB-6509#
CY-SB-6509#
CY-SB-6509#
   
  CY-SB-6509#sh module 
Mod Ports Card Type                              Model              Serial No.

--- ----- -------------------------------------- ------------------ -----------
1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-SUP2-2GE SAL09497B9D 2 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06200P5A 3 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06200P3V 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAD043601HW 5 0 SLB Application Processor Complex WS-X6066-SLB-APC SAD07130007 9 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 SAD043302DA Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
1 0015.c6b3.aa24 to 0015.c6b3.aa25 5.3 7.1(1) 12.1(26)E5 Ok 2 0009.1266.1f98 to 0009.1266.1f9f 2.1 5.4(2) 8.5(0.9)TFW3 Ok 3 0009.1266.1e50 to 0009.1266.1e57 2.1 5.4(2) 8.5(0.9)TFW3 Ok 4 00d0.c0d2.dff4 to 00d0.c0d2.dffb 1.3 5.4(2) 8.5(0.9)TFW3 Ok 5 0002.7ee5.0d64 to 0002.7ee5.0d6b 1.6 Unknown Unknown PwrDown 9 0030.19de.4dc4 to 0030.19de.4df3 1.1 5.4(2) 8.5(0.9)TFW3 Ok Mod Sub-Module Model Serial Hw Status
--- --------------------------- --------------- --------------- ------- -------
1 Policy Feature Card 2 WS-F6K-PFC2 SAL09507N7J 3.5 Ok 1 Cat6k MSFC 2 daughterboard WS-F6K-MSFC2 SAL1004BCT6 2.9 Ok

  Mod Online Diag Status
--- -------------------

  1 Pass
  2 Pass
  3 Pass
  4 Pass
  5 Unknown
  9 Pass
CY-SB-6509#sh module

Mod Ports Card Type                              Model              Serial No.

--- ----- -------------------------------------- ------------------ -----------
1 2 Catalyst 6000 supervisor 2 (Active) WS-X6K-SUP2-2GE SAL09497B9D 2 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06200P5A 3 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAL06200P3V 4 8 8 port 1000mb GBIC Enhanced QoS WS-X6408A-GBIC SAD043601HW 5 0 SLB Application Processor Complex WS-X6066-SLB-APC SAD07130007 9 48 48 port 10/100 mb RJ45 WS-X6348-RJ-45 SAD043302DA Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
1 0015.c6b3.aa24 to 0015.c6b3.aa25 5.3 7.1(1) 12.1(26)E5 Ok 2 0009.1266.1f98 to 0009.1266.1f9f 2.1 5.4(2) 8.5(0.9)TFW3 Ok 3 0009.1266.1e50 to 0009.1266.1e57 2.1 5.4(2) 8.5(0.9)TFW3 Ok 4 00d0.c0d2.dff4 to 00d0.c0d2.dffb 1.3 5.4(2) 8.5(0.9)TFW3 Ok 5 0002.7ee5.0d64 to 0002.7ee5.0d6b 1.6 Unknown Unknown PwrDown 9 0030.19de.4dc4 to 0030.19de.4df3 1.1 5.4(2) 8.5(0.9)TFW3 Ok Mod Sub-Module Model Serial Hw Status
--- --------------------------- --------------- --------------- ------- -------
1 Policy Feature Card 2 WS-F6K-PFC2 SAL09507N7J 3.5 Ok 1 Cat6k MSFC 2 daughterboard WS-F6K-MSFC2 SAL1004BCT6 2.9 Ok

  Mod Online Diag Status
--- -------------------

  1 Pass
  2 Pass
  3 Pass
  4 Pass
  5 Unknown
  9 Pass

CY-SB-6509#
CY-SB-6509#
CY-SB-6509#
   

  CY-SB-6509#sh module ContentSwitchingModule 5 % Incomplete command.    

  CY-SB-6509#sh module ContentSwitchingModule 5 rea CY-SB-6509#sh module ContentSwitchingModule 5 reals    

  real                  server farm      weight  state          conns/hits

-------------------------------------------------------------------------
 CSM module is offline.                 

Yahoo! Messenger with Voice. PC-to-Phone calls for ridiculously low rates.

[Non-text portions of this message have been removed]

--

Cisco Teknik Tartisma Listesi (Cisco-ttl)

Bu listede onerilen degisikliklerin uygulanmasindaki tum sorumluluk kullaniciya aittir. Liste yoneticileri, oneride bulunan liste uyeleri ya da bu uyelerin calistigi kuruluslar herhangi bir sekilde sorumlu tutulamazlar. Yahoo! Groups Links

<*> To visit your group on the web, go to:

    http://groups.yahoo.com/group/cisco-ttl/

<*> To unsubscribe from this group, send an email to:

    cisco-ttl-unsubscribe@yahoogroups.com

<*> Your use of Yahoo! Groups is subject to:

    http://docs.yahoo.com/info/terms/   Received on Tue May 30 11:57:29 2006

This archive was generated by hypermail 2.1.8 : Tue May 30 2006 - 11:57:34 EEST