Re: [cisco-ttl] controller e1 3/2 down problem

From: Devrim Yener KUCUK (dkucuk_at_cisco.com)
Date: Mon Aug 02 2004 - 14:06:51 GMT

  • Next message: Serhat Uslay: "Re: [cisco-ttl] controller e1 3/2 down problem"

    Merhaba

    Layer 1 active degilse , controller'un DOWN olmasi normal.

    Baglantiyi (kabloyu) ve "ISDN Switchtype" i kontrol edin oncelikle.
    Router network olmayacak di mi ? ( simulate network yapilabilir, isdn protocol-emulate network)

    Layer 1 active olursa layer 2 icin (debug isdn q921 )...

    Kolay gelsin

    Devrim

      ----- Original Message -----
      From: İsmail CAN
      To: cisco-ttl_at_yahoogroups.com
      Sent: Monday, August 02, 2004 5:43 PM
      Subject: [cisco-ttl] controller e1 3/2 down problem

      Merhaba,

      Arkadaslar bu konuda yardımcı olursanız cok sevinirim. Lutfen bu konuda gercekten yardıma ihtiycım var. Cok tesekkur ederim....

      Layer 1 active hale getiremiyorum alcatel hdsl 1512 modem ile as5350 bagli birbirine,
      aynı zamanda "sh controllers e1 3/2" yaptıgımda e1 3/2 down gorunuyor.
      "sh isdn status"
      as5350#sh isdn status
      Global ISDN Switchtype = primary-net5
      ISDN Serial3/2:15 interface
              dsl 1, interface ISDN Switchtype = primary-net5
          Layer 1 Status:
              DEACTIVATED
          Layer 2 Status:
              TEI = 0, Ces = 1, SAPI = 0, State = TEI_ASSIGNED
          Layer 3 Status:
              0 Active Layer 3 Call(s)
          Active dsl 1 CCBs = 0
          The Free Channel Mask: 0x00000000
          Number of L2 Discards = 0, L2 Session ID = 98
          Total Allocated ISDN CCBs = 0

      "sh controllers e1 3/2 "

      as5350#sh controllers e1 3/2
      E1 3/2 is down.
        Applique type is Channelized E1 - balanced
        Far End Block Errors Detected
        Receiver has loss of signal.
        alarm-trigger is not set
        Version info of slot 3: HW: 519, PLD Rev: 1
        Framer Version: 0x8
      Manufacture Cookie Info:
       EEPROM Type 0x0001, EEPROM Version 0x01, Board ID 0x05,
       Board Hardware Version 2.7, Item Number 73-5267-03,
       Board Revision A0, Serial Number JAE08083CU8,
       PLD/ISP Version <unset>, Manufacture Date 22-Feb-2004.
        Framing is CRC4, Line Code is HDB3, Clock Source is Line.
        Data in current interval (273 seconds elapsed):
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 273 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 273 Unavail Secs
        Data in Interval 1:
           344020 Line Code Violations, 61147 Path Code Violations
           1 Slip Secs, 660 Fr Loss Secs, 84 Line Err Secs, 0 Degraded Mins
           1 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 693 Unavail Secs
        Data in Interval 2:
           226022 Line Code Violations, 29065 Path Code Violations
           0 Slip Secs, 229 Fr Loss Secs, 37 Line Err Secs, 0 Degraded Mins
           5 Errored Secs, 3 Bursty Err Secs, 17 Severely Err Secs, 239 Unavail Secs
        Data in Interval 3:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 897 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 897 Unavail Secs
        Data in Interval 4:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 5:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 6:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 7:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 8:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 9:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 10:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 11:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 900 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 12:
           16384908 Line Code Violations, 196475 Path Code Violations
           244 Slip Secs, 850 Fr Loss Secs, 399 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
        Data in Interval 13:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 148 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 148 Unavail Secs
        Data in Interval 14:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 15:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 16:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 17:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 18:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 19:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 20:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 21:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 22:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 23:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 24:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 25:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Data in Interval 26:
           0 Line Code Violations, 0 Path Code Violations
           0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
           0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
        Total Data (last 26 15 minute intervals):
           16954950 Line Code Violations, 286687 Path Code Violations,
           245 Slip Secs, 9984 Fr Loss Secs, 520 Line Err Secs, 0 Degraded Mins,
           6 Errored Secs, 3 Bursty Err Secs, 17 Severely Err Secs, 10077 Unavail Secs
      as5350#

    ------------------------------------------------------------------------------
      Do you Yahoo!?
      New and Improved Yahoo! Mail - 100MB free storage!

      Bu listenin Cisco Systems ile herhangi bir baglantisi bulunmamaktadir.

      Listeden cikmak için cisco-ttl-unsubscribe_at_yahoogroups.com adresine bir e-posta gönderebilirsiniz.

            Yahoo! Groups Sponsor
                  ADVERTISEMENT
                 
           
           

    ------------------------------------------------------------------------------
      Yahoo! Groups Links

        a.. To visit your group on the web, go to:
        http://groups.yahoo.com/group/cisco-ttl/
          
        b.. To unsubscribe from this group, send an email to:
        cisco-ttl-unsubscribe_at_yahoogroups.com
          
        c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.



    This archive was generated by hypermail 2.1.5 : Mon Aug 02 2004 - 18:07:23 GMT