|
|
[cisco-ttl] Content CMS Kart Arızası
From: ersan tombalak <tombalak80_at_....>
Date: Tue May 30 2006 - 08:39:39 EEST
CMS hakkında bilgili olan arkadaşların yardımını bekliyorum. Contentle ile ilgili bilgiler Contentle ilgili bilgiler.....(Kırmızı satırlarda Slot 5 teki csm ile ilgili hatalar görülmektedir...)
00:00:42: RP: Currently running ROMMON from S (Gold) region
00:00:51: %SYS-5-CONFIG_I: Configured from memory by console
00:00:53: %SYS-5-RESTART: System restarted --
Cisco Internetwork Operating System Software
IOS (tm) c6sup2_rp Software (c6sup2_rp-JS-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2006 by cisco Systems, Inc.
Compiled Sun 01-Jan-06 06:25 by hqluong
00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start 00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 91 seconds 00:00:46: SP: SP: Currently running ROMMON from S (Gold) region 00:00:52: %SYS-SP-5-RESTART: System restarted --Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong 00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray 00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2 00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on. 00:00:58: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed. Attempting to diagnose the source of the problem and recover if possible. 00:00:58: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel. It has been disabled. Replace the line card. 00:00:58: %SM-SP-4-BADEVENT: Event 'powered_off' is invalid for the current state 'check_power_on': cygnus_oir_bay slot5 -Traceback= 4024CEFC 4023E1BC 403FFC24 406D0718 400FCD64 400FCD50 00:00:58: SP: Last transition recorded: (insert)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (yes_power)-> check_power_on 00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset) 00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online 00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset) 00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online 00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset) 00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online 00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset) 00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online 00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset) 00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online 00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset) 00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online 00:00:59: %OIR-SP-6-PWRFAILURE: Module 5 is being disabled due to power convertor failure 00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online 00:00:59: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request) 00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online 00:01:08: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics... 00:01:13: %SNMP-5-MODULETRAP: Module 1 [Up] Trap 00:01:13: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics 00:01:13: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online 00:01:29: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimum Online Diagnostics... 00:01:38: %SNMP-5-MODULETRAP: Module 9 [Up] Trap 00:01:38: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics 00:01:38: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now onlineCY-SB-6509>en Password: 00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start 00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 3343 seconds 00:00:46: SP: SP: Currently running ROMMON from S (Gold) region 00:00:52: %SYS-SP-5-RESTART: System restarted --Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong 00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray 00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2 00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on. 00:01:05: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed. Attempting to diagnose the source of the problem and recover if possible. 00:01:06: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel. It has been disabled. Replace the line card. 00:01:06: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request) 00:01:06: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset) 00:01:06: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset) 00:01:06: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset) 00:01:06: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset) 00:01:07: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset) 00:01:07: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset) 00:01:07: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset) 00:01:07: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset) 00:01:08: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics... 00:01:15: %SNMP-5-MODULETRAP: Module 1 [Up] Trap 00:01:15: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics 00:01:15: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online 00:01:39: %DIAG-SP-6-RUN_MINIMUM: Module 2: Running Minimum Online Diagnostics... 00:01:40: %DIAG-SP-6-RUN_MINIMUM: Module 4: Running Minimum Online Diagnostics... 00:01:40: %DIAG-SP-6-RUN_MINIMUM: Module 3: Running Minimum Online Diagnostics... 00:01:44: %SNMP-5-MODULETRAP: Module 2 [Up] Trap 00:01:44: %DIAG-SP-6-DIAG_OK: Module 2: Passed Online Diagnostics 00:01:44: %OIR-SP-6-INSCARD: Card inserted in slot 2, interfaces are now online 00:01:49: %SNMP-5-MODULETRAP: Module 4 [Up] Trap 00:01:49: %DIAG-SP-6-DIAG_OK: Module 4: Passed Online Diagnostics 00:01:49: %OIR-SP-6-INSCARD: Card inserted in slot 4, interfaces are now online 00:01:50: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimum Online Diagnostics... 00:01:53: %SNMP-5-MODULETRAP: Module 3 [Up] Trap 00:01:53: %DIAG-SP-6-DIAG_OK: Module 3: Passed Online Diagnostics 00:01:53: %OIR-SP-6-INSCARD: Card inserted in slot 3, interfaces are now online 00:02:02: %SNMP-5-MODULETRAP: Module 9 [Up] Trap 00:02:02: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics 00:02:02: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now onlineCY-SB-6509> CY-SB-6509# 00:15:06: %OIR-SP-6-REMCARD: Card removed from slot 5, interfaces disabled 00:15:19: %SNMP-5-MODULETRAP: Module 2 [Down] Trap 00:15:19: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed. Attempting to diagnose the source of the problem and recover if possible. 00:15:19: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel. It has been disabled. Replace the line card. 00:15:19: %SM-SP-4-BADEVENT: Event 'powered_off' is invalid for the current state 'check_power_on': cygnus_oir_bay slot5 -Traceback= 4024CEFC 4023E1BC 403FFC24 406D0718 400FCD64 400FCD50 00:15:19: SP: Last transition recorded: (remove)-> empty (remove)-> empty_clr_persist (remove)-> empty (insert)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (yes_power)-> check_power_on (timer)-> check_power_on (timer)-> check_power_on 00:15:19: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset) 00:15:19: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset) 00:15:19: %OIR-SP-6-PWRFAILURE: Module 5 is being disabled due to power convertor failure 00:15:19: SP: oir_disable_notice: slot5: lcp failed to go online 00:15:19: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request) 00:15:19: %SNMP-5-MODULETRAP: Module 3 [Down] Trap 00:15:19: SP: oir_disable_notice: slot5: lcp failed to go online 00:15:20: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset) 00:15:20: %SNMP-5-MODULETRAP: Module 4 [Down] Trap 00:15:20: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset) 00:15:21: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset) 00:15:21: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset) 00:15:21: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset) 00:15:21: %SNMP-5-MODULETRAP: Module 9 [Down] Trap 00:15:21: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset) CY-SB-6509# CY-SB-6509# CY-SB-6509# CY-SB-6509#sh module ContentSwitchingModule 5 reals real server farm weight state conns/hitsCSM module is offline. CY-SB-6509#sh module ContentSwitchingModule 5 reals 00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start 00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 4434 seconds 00:00:46: SP: SP: Currently running ROMMON from S (Gold) region 00:00:52: %SYS-SP-5-RESTART: System restarted --Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong 00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray 00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2 00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on. 00:00:58: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed. Attempting to diagnose the source of the problem and recover if possible. 00:00:58: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel. It has been disabled. Replace the line card. 00:00:58: %SM-SP-4-BADEVENT: Event 'powered_off' is invalid for the current state 'check_power_on': cygnus_oir_bay slot5 -Traceback= 4024CEFC 4023E1BC 403FFC24 406D0718 400FCD64 400FCD50 00:00:58: SP: Last transition recorded: (insert)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (yes_power)-> check_power_on 00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset) 00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online 00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset) 00:00:58: SP: oir_disable_notice: slot2: lcp failed to go online 00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset) 00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online 00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset) 00:00:58: SP: oir_disable_notice: slot3: lcp failed to go online 00:00:58: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset) 00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online 00:00:58: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset) 00:00:58: SP: oir_disable_notice: slot4: lcp failed to go online 00:00:59: %OIR-SP-6-PWRFAILURE: Module 5 is being disabled due to power convertor failure 00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online 00:00:59: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request) 00:00:59: SP: oir_disable_notice: slot5: lcp failed to go online 00:01:08: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics... 00:01:14: %SNMP-5-MODULETRAP: Module 1 [Up] Trap 00:01:14: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics 00:01:14: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online 00:00:53: %SNMP-5-COLDSTART: SNMP agent on host CY-SB-6509 is undergoing a cold start 00:00:53: %SYS-6-BOOTTIME: Time taken to reboot after reload = 4617 seconds 00:00:46: SP: SP: Currently running ROMMON from S (Gold) region 00:00:52: %SYS-SP-5-RESTART: System restarted --Cisco Internetwork Operating System Software IOS (tm) c6sup2_sp Software (c6sup2_sp-SP-M), Version 12.1(26)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Sun 01-Jan-06 07:13 by hqluong 00:00:54: %C6KENV-SP-4-FANVERCHK: Power-supply 2 inserted is only compatible with Version 1 fan-tray. Please make sure fan is low-output fan-tray 00:00:54: %OIR-SP-6-INSPS: Power supply inserted in slot 2 00:00:54: %C6KPWR-SP-4-PSOK: power supply 2 turned on. 00:01:00: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (Reset) 00:01:07: %DIAG-SP-6-RUN_MINIMUM: Module 1: Running Minimum Online Diagnostics... 00:01:13: %SNMP-5-MODULETRAP: Module 1 [Up] Trap 00:01:13: %DIAG-SP-6-DIAG_OK: Module 1: Passed Online Diagnostics 00:01:13: %OIR-SP-6-INSCARD: Card inserted in slot 1, interfaces are now online 00:01:15: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed. Attempting to diagnose the source of the problem and recover if possible. 00:01:15: %EOBC-SP-2-EOBC_JAM_RECOVERED: Module in slot 5 is jamming the EOBC channel. It has been disabled. Replace the line card. 00:01:15: %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (admin request) 00:01:15: %OIR-SP-3-PWRCYCLE: Card in module 2, is being power-cycled off (Reset) 00:01:15: %C6KPWR-SP-4-DISABLED: power to module in slot 2 set off (Reset) 00:01:16: %OIR-SP-3-PWRCYCLE: Card in module 3, is being power-cycled off (Reset) 00:01:16: %C6KPWR-SP-4-DISABLED: power to module in slot 3 set off (Reset) 00:01:16: %OIR-SP-3-PWRCYCLE: Card in module 4, is being power-cycled off (Reset) 00:01:16: %C6KPWR-SP-4-DISABLED: power to module in slot 4 set off (Reset) 00:01:17: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset) 00:01:17: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset) CY-SB-6509#sh module Mod Ports Card Type Model Serial No.
Mod Online Diag Status
CY-SB-6509# CY-SB-6509# CY-SB-6509# CY-SB-6509#sh module Mod Ports Card Type Model Serial No.
Mod Online Diag Status
Mod Ports Card Type Model Serial No.
Mod Online Diag Status
CY-SB-6509# CY-SB-6509# CY-SB-6509# CY-SB-6509#sh module ContentSwitchingModule 5 % Incomplete command. CY-SB-6509#sh module ContentSwitchingModule 5 rea CY-SB-6509#sh module ContentSwitchingModule 5 reals real server farm weight state conns/hitsCSM module is offline. Yahoo! Messenger with Voice. PC-to-Phone calls for ridiculously low rates. [Non-text portions of this message have been removed]
-- Bu listede onerilen degisikliklerin uygulanmasindaki tum sorumluluk kullaniciya aittir. Liste yoneticileri, oneride bulunan liste uyeleri ya da bu uyelerin calistigi kuruluslar herhangi bir sekilde sorumlu tutulamazlar. Yahoo! Groups Links <*> To visit your group on the web, go to: http://groups.yahoo.com/group/cisco-ttl/ <*> To unsubscribe from this group, send an email to: cisco-ttl-unsubscribe@yahoogroups.com <*> Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/ Received on Tue May 30 11:57:29 2006 This archive was generated by hypermail 2.1.8 : Tue May 30 2006 - 11:57:34 EEST |